Pentax Telescope R 315N User Manual

Instruction Manual  
Electronic Total Station  
R-300 SERIES  
R-315(N)/R-325(N)/R-335(N)  
R-322(N)/R-323(N)  
PENTAX Industrial Instruments Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRECAUTIONS REGARDING SAFETY・  
WARNING  
Do not stare into the laser beam directly as this may result in damage to your eyes.  
R-300 is a Class II Laser product. The reflectorless type is a Class IIIa (3R) laser  
product.  
Do not look into the laser radiation aperture directly as this may result in  
damage to your eyes.  
Never use the telescope to view intense light such as direct sunlight or sun-light  
reflected through a prism as this may result in loss of sight.  
Do not disassemble, modify or repair this product as there a risk of laser radiation.  
Do not aim the laser beam at a person as it is harmful to the eyes and body.  
Receive the examination treatment by the doctor when the eyesight or body trouble is  
doubted by any chance.  
Electro-Magnetic Compatibility (EMC):  
This instrument complies with the protection requirement for residential and commercial  
areas. If this instrument is used close to industrial areas or transmitters, the equipment can  
be influenced by electromagnetic fields.  
Do not use this product in a coal mine, in a location where there is a coal dust, or  
near flammable material as there is a risk of explosion.  
Do not disassemble, modify or repair this product as there is a risk of fire,  
electric shock and burn injury. If you think the product requires repair,  
contact the retail outlet where you purchased it or an authorized repair site.  
Only use the BC03 battery charger intended for this product as the battery  
charger. Use of another battery charger entails a risk of fire or burn injury  
from the battery bursting into flames due to possible differences in voltage  
or polarity.  
Do not use a damaged electric cord plug or loose electric outlet when  
charging as there is a risk of fire or electric shock.  
Do not charge the battery while covered by clothes or similar item as there  
is a risk of fire if the clothes ignite.  
Do not use the battery or charger when wet as there is a risk of fire and  
burn injury due to short-circuit.  
To prevent making short-circuit when removing the battery and charger from  
the case and storing them, apply electrically resistant tape to the poles of  
the battery. Storing the battery and charger as-is may result in fire or burn  
injury due to short-circuit.  
Do not throw the battery into fire or expose it to heat as there is a risk of  
Injury if it explodes.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P1  
PRECAUTIONS REGARDING SAFETY・  
CAUTION  
For security, please do the opening inspection and inspection every a fixed period  
and adjustment.  
When the laser beam enters eyes, an unexpected accident might be caused by the  
blink of eyes. Establish the laser product to avoid the height of eyes of a driving person  
and walker.  
Establish an instrument so that laser beam does not hit a reflection thing as a mirror  
and a glass window. The refection beam of the laser is also harmful in the human body.  
Besides the time when you measure the distance, cut off the power supply or shade  
the beam of aperture with caps.  
Keep the laser product in the place where the person who does not have the  
product knowledge such as children does not touch by mistake.  
Destroy the power supply mechanism of the instrument so as not to emit the laser  
beam when throwing away it.  
Do not remove the handgrip without good reason. If it does come off, be  
sure to attach it securely to the instrument with screws. If it is not fastened  
securely, the instrument may fall when you grasp the handgrip, leading to  
possible injury.  
Do not short the poles of the battery or charger as there is a risk of injury or  
fire.  
Do not touch any fluid which may leak from the battery as there is a risk of  
chemical burn injury or reaction.  
Do not insert or remove the electric plug with wet hands as there is a risk of  
electric shock.  
Do not use the case to stand on as it is slippery and unstable and may  
cause you to fall, resulting in possible injury.  
Be sure the tripod itself and the instrument on the tripod are both installed  
securely as insecure installation may cause the tripod to fall over or the  
instrument to drop, resulting in possible injury.  
Do not carry the tripod with the metal shoe pointing toward another person  
as the person may be injured if they strike him or her.  
The instrument contains a rechargeable battery and it is rechargeable.  
At the end of its useful life, it may be illegal to dispose of the battery.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check with your local solid waste officials for details for recycling.  
P2  
Usage Precautions  
Surveying instruments are high-precision instruments. In order to assure that the  
Electronic Total Station R-300 series product which you have purchased will  
provide long-lasting maximum performance, the precautions in this manual must  
be followed. Be sure to follow these instructions and use this product properly at  
all times.  
[Solar Observation]  
WARNING  
Never view the sun directly using the telescope as this may result in loss of  
sight. Never point the objective lens directly at the sun as this may damage  
internal components. When using the instrument for solar observation, be sure  
to attach the special solar filter (MU64) designed for this product to the  
objective lens.  
[Laser Beam]  
Do not stare into laser beam. R-300 is a class-II Laser product. The reflectorless  
type is a Class IIIa (3R) laser product.  
[EDM axis]  
The R series EDM is the red visible laser beam and the beam diameter is very small.  
The beam is emitted from the objective center. The EDM axis is designed to coincide  
with the telescope sight axis but both axes may not sometimes coincide slightly  
according to the intense temperature change and time lapse.  
[Target Constant]  
Confirm the Target Constant of the instrument before measurement.  
If a different constant is to be used, use the correct constant of the target. The  
constant is stored in the instrument's memory when turned off.  
[Reflectorless and Reflector sheet]  
The measurement range is determined by the white side of the Kodak Gray  
Card facing the instrument and by its surrounding brightness.  
There is a possibility that the range may vary when the target does not satisfy  
the conditions above at survey work.  
Pay attention to followings in case of distance measurement by Reflectorless.  
In case of resulting in low accuracy, perform the distance measurement by  
Reflector sheet or Prism. (R-315N/R-325N/R-335N/R-322N/R-323N)  
There is a possibility that correct distance measurement may be impossible by  
dispersion or reduction of laser beam when the laser beam comes into the  
target from diagonal angle.  
There is a possibility that the instrument cannot calculate correctly when  
receiving reflected laser beam from forth and back directions in case of  
measuring the target on the road.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P3  
PRECAUTIONS REGARDING SAFETY・  
There is a possibility that synthesized values are calculated and the distance  
may become longer or shorter than the actual one when the operator  
measure the target of slope or sphere or rugged shape.  
There is a possibility that the instrument cannot calculate correctly by  
collecting the reflected laser beam from a man or a car that comes and goes  
in front of the target.  
When using Reflector sheet, set the Reflector sheet to have its surface be  
approx. vertical to the aiming line. If it is positioned not to be approx. right  
angle, there is a possibility that correct distance measurement may be  
impossible by dispersion or reduction of laser beam.  
[Battery & Charger]  
Never use any battery charger other than the BC03 battery charger as this  
may result in damage to the instrument.  
If water should happen to splash on the instrument or the battery, wipe it off  
immediately and allow it to dry in a dry location. Do not put the instrument in  
the case until it is completely dry as this may result in damage to the  
instrument.  
Turn off the power when removing the battery from the instrument as  
removing the battery while the power is still on may result in damage to the  
instrument.  
The battery mark displayed on the instrument is only an estimate of remaining  
battery power and is not completely accurate. Replace the battery quickly  
when it is about to run down as the time a battery lasts on one charge differs  
depending on conditions of ambient temperature, and the measurement mode  
of the instrument.  
Confirm the battery level remaining before operating.  
[Auto focus]  
The Auto focus mechanism is very precise but will not function under every  
condition. Focusing depends on brightness, contrast, the shape and size of the  
target.  
In such a case, press the AF button and focus on the target by operating the  
Power focus key or the AF ring.  
[LD POINT, Laser pointer]  
When you make a correct direction using the “LD POINT”, aim the laser beam at the  
wall and mark the center and then confirm the discrepancy between the reticle center  
and the marked point beforehand.  
[Storage and Operating Environment]  
To prevent making short-circuit when removing the battery and charger from  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the case and storing them, apply electrically resistant tape to the poles of the  
battery. Storing the battery and charger as is may result in fire or burn injury  
due to short-circuit.  
P4  
PRECAUTIONS REGARDING SAFETY  
Avoid storing the instrument in places subject to extreme high, low or radically  
fluctuating temperature. (Ambient temperature range during use: -20°C to  
+50° C)  
Distance measurements may take longer when atmospheric conditions are  
poor such as when heat shimmer is present. When storing the instrument,  
always put it in its case and avoid storage in dusty location or location subject  
to vibration or extreme heat or humidity.  
Whenever there is a sharp temperature difference between the instrument's  
storage and usage locations allow the instrument to adjust to the ambient for  
an hour or more before use. Be sure to protect the instrument from the sun if  
the location is subject to intense direct sunlight.  
During surveys for which the survey precision or atmospheric measurement  
method has been defined measure the atmospheric temperature and  
pressure separately and enter those values rather than using the Automatic  
Atmospheric Correction function.  
The battery should be charged approximately once per month if the  
instrument is to be stored for an extended period of time. The instrument  
should also be removed from its case occasionally and aired out.  
In addition to these precautions, be sure to handle the instrument properly at  
all times following the descriptions given in the various sections of this manual  
to assure safe and proper measurements.  
[Transporting and Carrying the Instrument]  
Be careful to protect this instrument from shock of impact and excessive  
vibration which may result in damage during transportation and shipment.  
When transporting the instrument, always put it in the case and wrap shock-absorbing  
material around it and be sure it is handled as "FRAGILE".  
[Checks and Repairs]  
Always check the instrument before beginning work and check that the  
instrument is maintaining the proper level of precision. Pentax bears  
absolutely no responsibility for damages due to survey results obtained from  
surveys conducted without an initial instrument check.  
Never disassemble the instrument, battery or charger even if you do detect an  
abnormality as there is a risk of fire or electric shock due to short-circuit. If  
you think the product requires repair, contact the retail outlet where you  
purchased it or an authorized repair site.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P5  
CONTENTS  
PRECAUTIONS REGARDING SAFETY  
Safety Precautions  
Usage Precautions  
CONTENTS  
1 BEFORE USING THE INSTRUMENT  
1-1 Names of Parts  
1-2 Unpacking and Packing  
1-2 Standard equipment  
1-4 Attaching and Charging the Battery  
1-5 Attachment of Focus Battery  
2 DISPLAY AND KEYBOARD  
2-1 Display and Keyboard  
2-2 Operation Key  
2-3 Function Key  
2-4 Alphanumeric Input  
2-5 LD Point, Laser pointer  
3 PREPARATION FOR SURVEYING  
3-1 Centering and Leveling of the Instrument  
3-2 Laser Plummet  
3-3 Optical Plummet..(Option)  
3-4 .Leveling with Circular Vial  
3-5 Leveling with Electronic Vial  
3-6 Eyepiece Adjustment  
3-7 Target Sighting  
3-8 Attachment and Detachment of Tribrach  
4 TURNING THE POWER ON  
4-1 Turning the Power On and Off  
4-2 Adjusting LCD Contrast  
4-3 Adjusting Illumination Brightness  
4-4 Adjust Reticle Illumination  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P6  
1 BEFORE USING THE INSTRUMENT  
1 BEFORE USING THE INSTRUMENT  
1-1 Names of Parts  
Collimator  
Focusing knob  
Power focus key  
AF button  
Laser indicator  
Battery cap  
Eyepiece  
Instrument height mark  
Battery latch  
Circular level  
Display panel  
Battery pack  
Telescope tangent screw  
Telescope clamp screw  
Clamp screw  
Tangent screw  
Key board  
Circular level  
Leveling screw  
Clamp screw  
Detaching knob  
Base plate  
R-325(N)/R-322(N)/R-323(N): Detachable type  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P7  
1 BEFORE USING THE INSTRUMENT  
Top handle  
Objective lens  
Centering knob  
R-335 (N): Shift type  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P8  
1-2 Unpacking and Packing  
Unpacking the Instrument from the case  
q Set the case down gently with the lid facing upwards.  
w Open the latches while pressing down on the lock (safety mechanism) and  
open the lid of the case.  
e Remove the instrument from the case.  
Packing the Instrument in the case  
q Make sure the telescope is  
fairly level and lightly tighten  
the telescope clamp screw.  
w Line up the housing marks  
(round yellow marks on the  
instrument) and tighten the  
upper and lower clamp  
screws.  
e With the housing marks facing  
upward, set the instrument  
gently in the case without  
forcing it.  
r Close the lid to the case and  
secure the latches.  
1-3 Standard equipment  
Instrument  
Carrying case  
BP02 battery  
BC03/AC01 charger  
AF battery (CR-123A)  
Plumb bob  
Hexagonal wrench  
Rain cover  
Quick Reference Guide (Basic , PTL and PCS 330 procedures)  
CD-R (Basic operation & Special Functions manual)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P9  
1 BEFORE USING THE INSTRUMENT・  
1-4 Attaching and Charging the Battery  
Removing the Battery  
Turn the lock lever anticlockwise and remove the Battery.  
Lift up the battery pack and remove it from the instrument.  
Be absolutely sure to turn the power off when removing the battery as  
removing the battery while the power is still on may result in damage to the  
instrument.  
Attaching the Battery  
Align the guide pins on the battery pack with the guide grooves on the  
instrument and push the battery pack down into place.  
The battery is attached when you hear the top of the battery pack click into  
place.  
Turn the lock lever clockwise to fix.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P10  
1 BEFORE USING THE INSTRUMENT  
Remaining Battery Charge  
When the instrument's power is turned on, a battery mark "" will be  
displayed on the right of the display screen. This mark can be used to check the  
charge status of the battery.  
Low battery: Please change. Replace with the spare battery or charge.  
Charging the battery  
The battery BP02 is not charged at our factory shipment so charge it.  
For BP02 charge, use the special BC03 charger.  
[Connection of code ]  
Insert the output plug of the power supply code in Jack of the AC adaptor.  
Insert the output plug of the AC adaptor in Jack of the charger.  
Insert the power supply plug of the power supply code in the outlet of domestic use  
AC power supply (100V,50Hz-60Hz).  
[Installation of battery ]  
Draw the battery to the lock lever side and put it on the battery pocket. The battery is  
firmly installed on the battery pocket.  
Press down the battery and then slide it to the opposite direction of the lock lever.  
The lock lever goes up, and the battery is fixed.  
Under such a condition, if Connection of the code" is done, the charge with the  
battery is begun.  
P11  
[Detaching of battery]  
Press the lock lever and slide the battery to the lock lever direction.  
Detach the battery packing from the battery pocket.  
[Display panel]  
Power lamp  
Installation lamp  
Charging lamp  
Discharge  
lamp  
Discharge  
button  
Power supply lamp (red): Turns on when the power supply is turned on.  
Charge lamp (green): Turns on while charging and turns off when the charge is completed.  
Discharge lamp (yellow): Turns on when you push the discharge button.  
Turns off when the discharge is completed. .  
Installation lamp (red): Blinks or turns on when the battery packing is attached normally.  
Blinks when charge or discharge and turns on when charge is completed.  
(The charge lamp in the lower does not blink and does not turns on)  
Discharge button: Discharge lamp lights when you push this button, and the discharge of  
batterybegins.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P12  
[How to charge]  
It begins charging automatically when you set the battery packing in the charger which beams the  
power supply lamp.  
Leave just as it is until the charge is completed.  
When the charge is completed, the charge lamp is turned off.  
Detach the battery packing from the charger when the charge is completed.  
Refreshing of battery  
The use time shortens gradually by the phenomenon ofEffect of the memory" when the NiMH  
battery leaves capacity and repeats the charge. The voltage recovers after refreshing and the use  
time returns normally in such a battery. Please refresh one degree every five times of the charge.  
[Refreshing]  
Set the battery in the charger as well as the case of the charge. Push the electrical discharge button.  
The electrical discharge lamp lights and the electrical discharge begins.  
The electrical discharge lamp is turned off when the electrical discharge ends, the charge lamp lights,  
and the charge starts automatically. Leave just as it is until the charge is completed. When the  
charge is completed, the charge lamp is turned off. Detach the battery from the charger.  
[Time of refreshing and charge ]  
Battery BP02 is discharged from the state of a full charge at about 960 minutes and the charge is  
completed from the electrical discharge at about 130 minutes. However, the electrical discharge time  
is proportional to the remainder capacity of the battery. Moreover, the time required for refreshing  
might be different from the above-mentioned time according to a surrounding temperature and the  
state of the battery.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P13  
2 DISPLAY AND KEYBOARD  
2-1 Display and Keyboard  
Alphanumeric  
and +/- key  
Power supply key  
Function keys  
Illumination key  
ESC key  
Laser plummet and  
Electronic vial key  
2-2 Operation Key  
Key  
Description  
[POWER]  
[ESC]  
ON/OFF of power supply  
Returns to previous screen or cancels an operation.  
[Illumination]  
Turns the illumination of the LCD display and telescope reticle on and  
off.  
[ENT]  
Accepts the selected ( hilighted) choice or the displayed screen value.  
[Laser]  
Displays the laser plummet *1, electronic vial function, and the LD point  
screen when you push the laser plummet/electronic vial key.  
(Refer to 5-3 LD point function", 9-1-2 Laser plummet", and  
Leveling with 9-1-4 electron vial").  
*1:Only the product with the laser plummet function  
[Alphanumeric]  
[HELP]  
At the numerical value screen, the numerical value and the sign '.'  
displayed are input. The English characters printed right under  
numeric of each key are input.  
Pressing [lLLU]+[ESC] key causes a help menu to appear in A  
MODE or B MODE or causes a help message to appear.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P14  
2 DISPLAY AND KEYBOARD  
2-3 Function Key  
Display  
Mode A  
F. Key  
Description  
F1  
Pressing this key one time measures the distance and  
measurement type can be selected by Initial Setting 2.  
Pressing this key twice measures the distance by cm  
unit and another measurement type can be selected by  
Initial Setting 2.  
MEAS」  
[TARGET]  
F2  
Select the target type by following order.  
SHEET/ REFRECTORLESS /PRISM  
(Reflectorless type instrument)  
SHEET/PRISM/REFRECTORLESS  
(Prism type instrument)  
[0 SET]  
[DISP]  
F3  
F4  
Resets the horizontal angle to 0°0' 0" by pressing twice.  
Switches the display composition in the order  
"H.angle/H.dst./V.dst.", "H.angle/V.angle/S.dst." and  
"H.angle/V.angle/H.dst./S.dst./V.dst.".  
Switches the screen between MODE A and MODE B.  
[MODE]  
F5  
Mode B  
[S.FUNC]  
F1  
F2  
PowerTopoLite  
[ANG SET]  
Brings up the angle setting screen for setting angle-  
related parameters  
(H.ANGLE/%GRADE, H.ANGLE INPUT and R/L  
REVERSE).  
[HOLD]  
[CORR]  
F3  
F4  
Pressing this key twice retains (holds) the horizontal  
angle shown on the display.  
Brings up the screen for changing the Target constant,  
Temperature, Pressure setting.  
Other functions  
F1  
F2  
F1  
F2  
F3  
F3  
Moves the cursor to the left.  
Moves the cursor to the right.  
Goes back five Items on the screen  
Goes forward five items on the screen.  
Changing the Reticle illumination when pressing Illumination key  
Moves the cursor up  
[]  
[]  
[]  
[]  
RETICLE  
[]  
LCD  
[]  
ILLU  
[CLEAR]  
[SELECT]  
F4  
F4  
F5  
F5  
F5  
Changing the LCD contrast when pressing Illumination key  
Moves the cursor down  
Changing the LCD illumination when pressing Illumination key  
Clear the figure  
Open the selection window  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P15  
[How to move the menu number]  
Example:  
ANGLE SET  
1.ANGLE/%GRADE:ANGLE  
2.H.ANGLE INPUT :092 30’ 20”  
3.R/L REVERSE : RIGHT  
The cursor is located at Menu 1.  
SELECT  
ANGLE SET  
1.ANGLE/%GRADE:ANGLE  
2.H.ANGLE INPUT :092 30’ 20”  
3.R/L REVERSE : RIGHT  
Press the numeric key 0 and 2  
to move to Menu 2.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P16  
2 DISPLAY AND KEYBOARD  
2-4 Alphanumeric Input  
The point name is input by the Alphanumetric keys as following.  
Key  
Letter under Key  
Letter & Figure order to input  
[0]  
[1]  
[2]  
[3]  
[4]  
[5]  
[6]  
[7]  
[8]  
[9]  
[.]  
[@][.][_][-][:][/][0]  
PQRS  
TUV  
WXYZ  
GHI  
JKL  
MNO  
[P][Q][R][S][p][q][r][s][1]  
[T][U][V][t][u][v][2]  
[W][X][Y][Z][w][x][y][z][3]  
[G][H][I][g][h][i][4]  
[J][K][L][j][k][l][5]  
[M][N][O][m][n][o][6]  
[空白][?][!][_][ ][^][|][&][7]  
[A][B][C][a][b][c][8]  
[D][E][F][d][e][f][9]  
[.][,][:][;][#][(][)]  
ABC  
DEF  
[+/-]  
[+][-][*][/][%][=][<][>]  
2-5 LD POINT, Laser Pointer  
The Laser pointer function appropriates the laser beam to aiming point and the watching confirmation can  
be done.  
When the [LD POINT] key is pushed while pushing the [Laser] key, the Laser pointer function is  
turned on. The distance measuring beam lamp blinks and the “  
" mark on the left of the screen  
blinks while the Laser pointer function is operating.  
If the [Laser] key is pushed and the [LD POINT] key is pushed while the Laser pointer function is  
operating, the Laser pointer function is turned off.  
The beam of the sun is strong and the watching confirmation is difficult at daytime outdoor.  
The laser beam is designed as the beam cannot be watched from eyepiece.  
Please appropriate the laser beam to the wall and mark the center, and confirm the amount of the gap  
(horizontal angle and vertical angle of a cross line ) beforehand when working like accurately putting out  
the direction by using the Laser pointer function.  
Please do not look at the laser source of beam directly.  
This product is Class 2 of the laser safety standard of JIS Radiation safety standard of the laser  
product".  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P17  
3
PREPARATION FOR SURVEYING  
3 PREPARATION FOR SURVEYING  
3-1 Centering and Leveling of the Instrument  
Setting up the instrument and the tripod  
Adjust the tripod legs so that a height suitable for observation is obtained  
when the instrument is set on the tripod.  
Set the tripod and fix the metal shoes firmly  
into the ground so that the tripod head is as level as  
possible, and the Tripod head coincides with the  
station on the ground. Fasten the leg screws.  
If the tripod head is mis-leveled by the action of  
fixing the metal shoes into the ground, correct the  
level by extending or retracting each leg of the tripod.・  
Instrument  
Contract  
Base plate  
Tripod head  
Metal shoe  
Center screw  
3 PREPARATION FOR SURVEYING  
3-2 Laser plummet  
Laser plummet model  
The laser plummet is not set to be ON at factory shipping. The laser plummet operation of power  
supply ON can be set by command No520, LD PLUM & E VIAL.  
[For the Detaching type laser plummet equipment model ]  
Turn on the laser plummet function by pushing the Laser key.  
Match the position with the leveling screw so that the laser mark may come on ground mark.  
[For the Shift type laser plummet equipment model ]  
Turn on the laser plummet function by pushing the Laser key.  
Match the position by the tripod so that the laser mark may come on the ground mark.  
The plumb fixation screw is loosened, and the upper plate is pushed by the tip of a finger, and a  
central mark is matched to the ground mark.  
Tighten the plumb fixation screw.  
Loosen the horizontal fixed screw, and rotate the instrument by 90°, and confirm the vial of the  
circular vial is at the center at any position.  
Correct the vial with the leveling screw when the vial comes off from the center.  
[Brightness adjustment of laser]  
Neither a state of the surface of ground mark nor a surrounding environmental factor might see the  
laser spot easily. Please adjust the brightness of the laser if necessary.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P18  
If the Laser key is pushed and the laser plummet  
key is pushed, it becomes the brightness  
adjustment screen of the laser plummet device.  
DOWN  
UP  
Adjustment LD plumb power  
The screen becomes dark by key and  
DOWN  
UP  
becomes bright by key  
ELECTRONIC VIAL  
T. COMP.  
The adjustment is completed with the ENT key  
and it returns to electronic vial screen.  
The brightness adjustment step of the laser is 10
Even if the brightness of the laser plummet is li
to check visually it occasionally. In this case, it b
make a few shadows with container case or your
The laser plummet is adjusted to be within ±0.8mm at the instrument height at factory shipping.  
Please confirm the amount of the gap (direction of X and Y direction) with the laser plummet  
beforehand compared with plumb bomb etc. w
perpendicular direction using the laser plumme
TILT LD POINT  
PLUM.ADJ  
SENS.  
Please do not look at the laser source of beam directly.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P19  
3-4  
Leveling with Circular vial  
Tripod is matched according to the following points, and expand and contract and match the vial of  
the Circular vial to the center of the circle.  
Shorten a leg which is the nearest the inclination of the vial or extend the furthest leg and draw  
the vial to the center.  
The other one leg is put, and next, expand and contract and put the vial in the center. At this  
time, the foot is not hung to the ferrule and the position of the ferrule does not shift.  
Electronic vial  
T.COMP  
ON  
3-5  
Leveling with Electronic vial  
[Electronic vial screen]  
1. If the Laser key is pushed, it becomes a  
display screen in the Electronic vial.  
LD POINT  
PLUM ADJ  
SENS.  
2. It returns to the former screen by the [ESC] key.  
When R-300 instrument is seen at the position of Left circle position", the screen in the  
electronic vial becomes a relation with a correct movement of the vial. Please note that the  
movement of the vial becomes opposite direction if it sees at the position of Right circle  
position".  
When instrument is within the tilt compensation range, length and sidewise±3', “ON” is  
displayed at the right screen, “ OVER” is displayed beyond the limits of range and “NIL” is  
displayed at no compensation setting.  
With command No "520" or "Initial setting 2", when the [TILT DISP] is selected as ON, the  
[F1 -TILT] of the vial screen becomes effective. The Vial tilt value is indicated when pushing  
the [TILT] key. With “TILT DISP.UNIT” of the Initial setting 2, 5” or 2” can be selected.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P20  
[Leveling]  
Rotate instrument horizontally and make two Leveling screws  
arbitrarily chosen parallel to the display.  
Turn on the Electronic vial function by pushing the Laser key.  
Put the vial of the Circular vial in the center of the circle when  
it is displayed on the display screen, TILT OVER”  
confirmation " .  
Leveling screw  
Turn two Leveling screws arbitrarily chosen in an opposite  
direction mutually and put the vial of the horizontal Electronic  
vial in the center. (Figure A)  
Put the vial of the lengthwise Electronic vial in the center by  
operating the Leveling screw of one remainder. (Figure B)  
The procedures are different according to the state of the  
Automatic inclination correction.  
[When using the Automatic inclination correction by 2 axes ]  
Please read procedure because the horizontal angle and the perpendicular angle error by a  
perpendicular axis are automatically corrected.  
[When using the Automatic inclination correction by 1 axis ]  
The instrument is horizontally rotated by 180 degrees after the vial of an Electronic vial is adjusted on the  
center at a Left circle position side and confirm that the vial of the vial is at the center at the right circle  
position.  
[When using the Automatic inclination correction by 0 axis ]  
Confirm the vial is at the center even if the instrument is rotated by each 90°.Confirm whether the  
instrument is on the ground mark. When you can confirm it is just on the mark loosen the center  
screw and move the instrument on the ground mark correctly and fix the instrument by a center  
screw. Repeat from to .  
3-6 Eyepiece Adjustment  
Eyepiece adjustment  
The eyepiece adjustment is performed before  
target sighting.  
Remove the telescope lens cap.  
Point the telescope at a bright object, and rotate  
the eyepiece ring full counter-clockwise.  
Look through the eyepiece, and rotate the  
eyepiece ring clockwise until the reticle appears  
as its maximum sharpness.  
When looking into the eyepiece, avoid an intense look to prevent parallax and  
eye fatigue.  
When it is hard to see the reticle due to poor brightness, press Illumination key to  
illuminate it . For adjusting intensity of brightness, refer to page X.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 PREPARATION FOR SURVEYING・  
[Target sighting by Auto focus]  
The Auto focus of R-300 series has following two modes.  
1. Normal mode : Pressing AF button focuses on the target.  
2. Continuous mode : Pressing AF buttons for two seconds beeps, and releasing  
the key enters into the Continuous mode. This mode  
enables you to perform the Auto focus approx. for one  
minutes only by sighting the telescope and chasing the  
target.  
3 PREPARATION FOR SURVEYING  
[Auto focus :Target sighting by Normal mode]  
q Loosen the telescope clamp and horizontal clamp screws.  
w Point the telescope at the target using a collimator.  
e Tighten the above two screws.  
r Adjust the eyepiece.  
t Look through the telescope and press the AF button. Move your eye vertically  
and horizontally to see if the target image moves in relation to reticle.  
y Stay the reticle accurately on the target using telescope and horizontal  
tangent screws.  
If the target image does not move, there is no parallax. If it moves, eliminate  
the parallax.  
Even when vertical angle measurement is not performed, it is recommended  
that the target should be placed at the reticle center.  
Operating the Power focus key rotates the AF ring, so do not touch it while it  
P22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 PREPARATION FOR SURVEYING  
[Auto focus :Target sighting by Continuous mode]  
Loosen the telescope clamp and horizontal clamp screws.  
Point the telescope at the target using a collimator.  
Tighten the above two screws.  
Adjust the eyepiece.  
Look through the telescope and then press the AF button for two seconds to  
beep, and release the key to enter into the Continuous mode.  
Stay the reticle accurately on the target using telescope and horizontal  
tangent screws.  
Point the telescope to the next target as well.  
Keep the target close to the reticle center when chasing it by the Continuous  
mode.  
Continuous mode automatically ceases after approx. one minute.  
Pressing the AF button or operating the Power focus key releases the  
continuous mode.  
Operating the Power focus key rotates the AF ring, so do not touch it while it  
is rotating.  
3 PREPARATION FOR SURVEYING  
[Auto focus :Target sighting by Power focus mode]  
Loosen the telescope clamp and horizontal clamp screws.  
Point the telescope at the target using a collimator.  
Tighten the above two screws.  
Adjust the eyepiece.  
Look through the telescope, and then operate the Power focus key and focus  
on the target.  
Stay the reticle accurately on the target using telescope and horizontal  
tangent screws.  
Tilting the Power focus key "clockwise" makes it possible to focus on closer  
range and "counterclockwise" makes on further range.  
Tilting angle of the Power focus key makes it possible to perform following  
Tripod focusing speeds.  
Low speed : When tilted to middle position by approx. 5 degrees  
Middle speed : When tilted fully by approx. 10 degrees  
High speed : When tilted fully by approx. 10 degrees and passed one  
second  
Operating the Power focus key rotates the AF ring, so do not touch it  
while it is rotating.  
P23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 PREPARATION FOR SURVEYING  
[Target sighting by Manual focus]  
Loosen the telescope clamp and horizontal clamp screws.  
Point the telescope at the target using a collimator.  
Tighten the above two screws.  
Adjust the eyepiece.  
Look through the telescope and then rotate the AF ring and stop it where the  
target can be seen clearly and the target image does not move in relation to  
reticle even if your eye is vertically and horizontally moved.  
Stay the reticle accurately on the target using telescope and horizontal  
tangent screws.  
The AF ring rotation "clockwise" makes it possible to focus on closer range  
and "counterclockwise" makes it possible to focus on further range.  
3 PREPARATION FOR SURVEYING  
3- 8 Attachment and Detachment of Tribrach  
The tribrach of R-325 is detachable from the instrument if required when  
replacing the instrument with a target or unit prism for example.  
Detachment  
First loosen the recessed screw with a screwdriver, then rotate the locking knob  
until the arrow points upward, and lift the instrument up.  
Attachment  
Mount the instrument on the tribrach with the guide marks coinciding, and rotate  
the locking knob until the arrow points downward.  
The guide and guide mark must be fitted to attach the instrument  
When the tribrach does not need to be attached or detached or instrument is to  
be transported, tighten the recessed screw with a screwdriver to fix the locking  
knob.  
P24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 TURNING THE POWER ON  
4 TURNING THE POWER ON  
4-1 Turning the Power On and Off  
Pressing the [POWER] key causes the initial  
screen.  
(The [POWER] key is also used to turn the  
power off.)  
After a few seconds, it turns to Electronic vial  
screen. Move the vials to center by adjusting  
the leveling screws.  
Pressing the [ENT] key views the angle  
and distance measurement screen.  
The Auto Power Off function will automatically turn the power off if no  
operations are performed for approximately 10 minutes. (Factory default  
setting)  
The [POWER] key is controlled by software in the instrument while it is  
working, and this key is valid only when turning off causes no problem.  
The value displayed when the power was last time turned off will be displayed  
for the horizontal angle. If this horizontal angle is not needed, please perform  
horizontal angle 0 SET.  
For details on resetting the horizontal angle 0 ............See page X.  
For details on changing the horizontal angle from  
clockwise to counterclockwise ...............................See page X.  
For details on measuring the vertical angle .................See page X.  
For details on distance measurement .........................See page X  
For details on the automatic power-off function ..........See page X  
For details on the Electronic vial  
See page X  
P25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 TURNING THE POWER ON  
4-2 Adjusting LCD Contrast  
Press [F4] while holding down the Illumination key  
to access the screen for adjusting LCD  
contrast.  
Pressing [F1] [ ] will lighten the  
contrast, while pressing the [F2] [ ] will  
darken the contrast.  
Press [ENT] to exit adjustment mode and  
return to the previous screen.  
Pressing the Illumination key views the F3-RETICLE, F4-LCD and F5-ILLU.  
LCD contrast may be adjusted as necessary at any time.  
The contrast may be adjusted to any one of 25 levels.  
LCD contrast may be unappealing under certain environmental conditions  
such as high temperature. Adjust the LCD contrast as described above in  
such situations.  
P26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 TURNING THE POWER ON  
4-3 Adjusting Illumination Brightness  
Press [F5] while holding down the Illumination key  
to access the screen for adjusting illumination  
brightness.  
Pressing the [F1]  
while pressing the [F2]  
brightness.  
will decrease brightness,  
will increase  
Press [ENT] to exit adjustment mode and  
return to the previous screen.  
Pressing the Illumination key views the F3-RETICLE, F4-LCD and F5-ILLU.  
Illumination brightness of the LCD screen and telescope reticle may be  
adjusted as necessary at any time.  
Illumination brightness may be adjusted to any one of 10 levels.  
4-4 Adjusting Reticle Illumination  
Press [F3] while holding down the Illumination key to access the screen for adjusting  
reticle illumination. The procedure to adjust the reticle illumination is the same way as  
4-3.  
Pressing the Illumination key views the F3-RETICLE, F4-LCD and F5-ILLU.  
P27  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Stereo System VSX 48 User Manual
Peerless Industries TV Mount PF640 User Manual
Philips DVD Recorder DVDR615 User Manual
Philips Home Theater System HTS2500 12 User Manual
Philips Speaker System SDJ6051 User Manual
Philips Stereo System CDC 486 User Manual
Pioneer CD Player DRM 624X User Manual
Polycom Cell Phone 300 and 310 User Manual
Poulan Snow Blower PR10527ESA User Manual
Proline Ventilation Hood PLS1570 User Manual